Membrane basics

8040 membrane elements


The standard industrial size: 1016 mm long, about 201 mm in diameter. Dimensions, membrane area and limits per brand, from the manufacturers' data sheets.

Dimensions

Length1016 mm (40.0")
Diameter200 to 201 mm (7.9")
Permeate tube, inner diameter28.6 mm (1.125"); some models 38.1 mm (1.50")
Membrane area20.9 to 40.9 m², depending on spacer and model
Usual designIndustrial, fibreglass wrap with fixed ATDs; sanitary versions are the exception

8040 elements by brand

Click a model for its product page, data sheet and quote. Limits are maximum values from each data sheet; the data sheet of the actual element governs.

BrandModelProcessDesignSpacerAreaMax. pressureMax. temp.pH, cleaning
Nitto (Hydranautics)CPA3ROIndustrial34 mil37.2 m²41.4 bar45 °C1 to 12.5
Nitto (Hydranautics)ESPA2-LDRO, low energy, low foulingIndustrial34 mil37.2 m²41.4 bar45 °C1 to 12
Nitto (Hydranautics)ESNA1-LF-LDNFIndustrial34 mil37.2 m²41.4 bar45 °C1 to 12 (25 °C, 30 min)
Nitto (Hydranautics)HYDRACoRe50-LDNF, 1,000 Da, chlorine resistantIndustrial, FRP hard shell34 mil37.2 m²41.4 bar45 °C1 to 12 (below 35 °C)
MANN+HUMMELTRISEP 8040-X20-TSARO, low foulingIndustrial34 mil33.9 m²41 bar45 °C1 to 12
MANN+HUMMELTurboClean 8040-TS40-31NFSanitary style, hard shell31 mil33.0 m²55 bar50 °C1 to 12
MANN+HUMMELTurboClean Bev 8040-UFUF, 10,000 Da, PESSanitary style, hard shell, with ATDs31 mil33.0 m²21 bar50 °C1 to 12
MANN+HUMMELTurboClean Bev 8040-MFMF, 0.2 µm, PVDFSanitary style, hard shell, with ATDs47 mil, parallel26.9 m²10.3 bar50 °C1 to 12
VeoliaAK8040F 400RO, low energyIndustrial, fibreglassnot stated37.2 m²41.4 bar50 °C1 to 13
VeoliaDuracon RO5 8040C35RO, hot-water sanitisable (90 °C)Sanitary, cage35 mil31.9 m²82.7 bar*50 °C1 to 12 (25 °C)
VeoliaGK8040F30UF, 3,500 DaIndustrial, fibreglass30 mil33.8 m²27.6 bar50 °C1 to 13
UNISOLFG UNF90 8040MNFIndustrial, fibreglass34 mil37 m²40 bar45 °C2 to 12
UNISOLSN UNF90 8040 (B)NFSanitary, net wrap, with ATD31 mil36 m²55 bar50 °C1.8 to 11

Replacing an 8040: what to check

8040 elements from different makers share the same outer envelope within a few millimetres. A one-to-one swap still needs five checks:

  • Permeate tube. Most 8040 elements have a 28.6 mm (1.125") inner diameter; some have 38.1 mm (1.50"). The interconnectors must match.
  • Male or female permeate tube, and the position of the brine seal.
  • Membrane chemistry and limits: pressure, temperature, pH and chlorine must fit your process and cleaning (CIP) regime.
  • Feed spacer: a different spacer changes the pressure drop and the cleanability.
  • Design: sanitary or industrial. A food process needs an element with food-contact compliance on its data sheet.

Sanitary 8040: the exception

The normal sanitary size is 8038, without ATDs. Sanitary 8040 elements exist for specific duties, such as hot-water sanitisation, in cage-wrap or hard-shell designs or with ATDs.

Questions

What size is an 8040 membrane?

1016 mm (40 inch) long and 200 to 201 mm (7.9 inch) in diameter. The permeate tube usually has an inner diameter of 28.6 mm (1.125 inch).

Are 8040 elements from different brands interchangeable?

Usually in size, but check the permeate tube diameter (28.6 or 38.1 mm), male or female connection, brine seal position, spacer and the membrane limits before swapping.

How much membrane area does an 8040 element have?

Between 20.9 and 40.9 m² in the data sheets we use. A thicker feed spacer leaves room for less membrane.

Is there a sanitary 8040?

Yes, as an exception, for example for hot-water sanitisation. The normal sanitary size is 8038.

What do you need for a quote?

Current brand and type, quantity, and the application: product, temperature, pH and cleaning (CIP) regime.

High pressure or low flux?

Tell us what you run into. We like to think along with you, no strings attached.